Connecting the thermostat to the heat supply: Pokrokova instruction

Today, more and more wide as an alternative to the traditional convection supplementary heating, the use of "warm" pidlogs. And as cable systems are the most popular in the zamіsk houses, then the lords of the місі apartments vvazhayut for better zastosovuvat plіvkovі, іnfrachervonі pokrittya.

However, for automating and improving the energy efficiency of robots, the operation of any electrical systems, heat supply is not sufficient. Today, different systems are being released with the temperature regime of warm sub-logs, which can be easily connected independently.

For the connection, a minimum of a tool is required, which will sound victorious when performing electrical work:

  • a set of spins;
  • side cutters with insulated handles;
  • indicator twist;
  • pliers;
  • maybe .

The sequence of installation and connection of the thermostatic outbuilding is coming:

  1. Before the beginning of the installation, it is necessary to designate the place, de-roof the thermostat, until it is necessary to supply the life line with a voltage of 220.0 volts. Ring for the connection of the vicorous socket.
  2. When laying the cable, place the temperature sensor installed. The temperature sensor is guilty of roztashovuvatisya on a functionally important, vіlnіy type of furniture dilyantsі living accommodations. To change the input wires, the sensor must be placed in direct proximity to the control unit.
  3. When installing a sub-log with cable heating, which is filled with a concrete screed, the wire that connects the control and monitoring unit with a temperature sensor is to blame for the provisions of the corrugated pipe. Zavdyaky this temperature sensor can be easily dismantled and replaced at a different exit from the fret.
  4. When laying the heating pad, the temperature sensor is simply glued with a special adhesive tape to the bottom side of the heating pad.
  5. After completion of the work on the installation of the heating element, install the regulator on the spot and connect to the new sensor. In order to avoid breaking through the strobe at the wall, when laying the heating pad, the wire along the wall can be laid or with a special decorative overlay.
  6. At times of independent obshtuvannya heat supply, if the heating cable is bathed around the thermoregulatory outbuilding, when it is connected, it is necessary to set the maximum intensity, so that the heating is slowed down. Even if it is less, it is allowed for switching by thermostat contacts, then the cable connection should be carried out directly to the annex. In order for the heating voltage to exceed the maximum allowable switching voltage, it is necessary to install an intermediate magnetic starter, the contacts of which should be switched on - a vimic cable.
  7. Connecting the cable to the temperature sensor to the temperature controller, and to the temperature control unit itself to the wire, is carried out according to the installation instructions for a specific model.
  8. After connecting the heating cable and the dart of the wine sensor, carry out a test without switching on the extension.

Trial start sequence

The reason for this comfort of being warm and fluent is unlikely to be apparent, as the installation of such a connection to a temperature-controlled outbuilding was wrong or due to defects. With any trial included, that re-verification is an even more important step.

The stinks pass under the control of the master of the life, which can be implied that the electric heating system can be deprived of the system without sight.

The sequence of rechecking and trial run is coming:

  • revise the reliability of contact details;
  • supply voltage to the block with a voltage of 220.0 volts;
  • on the panel keruvannya prilada set the minimum temperature value;
  • turn on the supply of the heating element with a toggle switch;
  • set the maximum temperature regime, with which the sleepwalker is responsible for the characteristic clatter, which is to indicate about the fading of contacts, which are switched;
  • by protyag doby reverify the superiority of robots in different modes.

Attach that connection scheme

Connecting an electronic thermostat to a water heating system

With a different thermostat for heating, a system of heat and cold water controls the temperature and a switch for a servo drive that controls the supply of hot water. The overall scheme for the installation of a thermostat is similar to the sequence of installation of a thermostat for electric heat supply. However, there are some nuances here.

The sequence of installation operations for the heating water system is as follows:

  1. A wine temperature sensor is installed at an uninterrupted proximity to the ceramic block at a height of 1.0 ... 1.2 meters above the level of the log.
  2. Lay the lances for the electric supply of the thermostat and connect the temperature sensor to the fitting;
  3. If it is transferred electrically by a servo drive from a wired connection without a middle connection to the controller, lay a cable from the servo drive to the thermostat;
  4. Yakshcho keruvannya by a servo drive without a drotove - zdіysnyuyut regulation of the radio keruvannya unit;
  5. Rechecking the temperature in different areas of the living quarters is carried out with the help of a standard thermometer. For this, set the thermostat to the required temperature regime and after 2-3 years, monitor the temperature near the appliance and the most distant view point. The indication of the thermometer is due to the mother of the minimum water.

At the end, designate that most of the current models of thermostats are universal fittings. Stinks with success can zastosovuvatisya not only for heat supply, but also for the automation of electric boilers.